Felcom 54 IEC Appliance Inlet C14 Modular Assembling Options
Felcom 54 IEC Appliance Inlet C14 Modular Assembling Options
Felcom 54 IEC Appliance Inlet C14 Modular Assembling Options
Felcom 54 Snap-in mounting
Snap-in mounting
Felcom 54 IEC Appliance Inlet C14 Modular Assembling Options
Felcom 54 IEC Appliance Inlet C14 Modular Assembling Options
Felcom 54 IEC Appliance Inlet C14 Modular Assembling Options
Felcom 54 IEC Appliance Inlet C14 Modular Assembling Options
Felcom 54 IEC Appliance Inlet C14 Modular Assembling Options
Felcom 54 IEC Appliance Inlet C14 Modular Assembling Options
Felcom 54 Snap-in mounting
Felcom 54 IEC Appliance Inlet C14 Modular Assembling Options
Felcom 54 IEC Appliance Inlet C14 Modular Assembling Options
Felcom 54 IEC Appliance Inlet C14 Modular Assembling Options

Series: Felcom 54

Free Sample Request

IEC Appliance Inlet C14 Modular Assembling Options

73 Variants


Connectors (Inlets/Outlets)

C14
Connector Logo
70° C
F
Connector Logo
70° C

Description Felcom 54

Description

  • Panel mount: Snap-in version from front side
  • 2 - 5 Functions: Appliance Inlet Protection class I, Connector, Line Switch 2-pole, Fuseholder for fuse-links 5 x 20 mm 1  or 2 pole, Line filter in standard and medical version
  • Solder terminals 3.5 x 0.8 mm or quick connect terminals 6.3 x 0.8 mm

Characteristics

  • Modular component selection
  • Individual components soldered on a printed circuit board
  • Plug removal necessary for fuse-link replacement
  • Technical data of filter-components see blockfilter type 5500
  • Fully insulated from the rear
  • Suitable for use in equipment according to IEC/UL 60950
    Suitable for use in medical equipment according to IEC/UL 60601-1

Other versions on request

  • Line switch with other rocker marking
Date Subcategory Language Title Download
21/02/2019
Flyers English Flyer Components and Solutions for Medical Equipment
04/02/2019
White Paper English White Paper Safety in medical Equipment
09/08/2018
White Paper English White Paper Cord retention
13/07/2018
PCN English All connectors PG06 PCN Change of configuration code PG06
06/04/2018
White Paper English White Paper Mating Connectors English
15/12/2017
White Paper English White Paper Components and IEC 60335-1
24/11/2017
White Paper English White Paper Leakage currents
24/11/2017
White Paper English White Paper Components and IEC 60335-1
09/09/2017
White Paper English White Paper Power Consumption

Ratings IEC

Ratings IEC


The electrical characteristics describe the approved operating values for the state of rated current and rated voltage considering the mentioned conditions.

General information on electrical characteristics colors of fuses
Ratings IEC, UL/CSA

General information on the rated current and the rated voltage at EMC products
Rated Voltage
Rated current

The values are different depending on the approval body and therefore are referenced in the corresponding admission cards for the respective product families. Details about the approvals and ratings are listed in the data sheets.

Search approval information for different families

Approvals

1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz

Ratings UL/CSA

Ratings UL


The electrical characteristics describe the approved operating values for the state of rated current and rated voltage considering the mentioned conditions.

General information on electrical characteristics colors of fuses
Ratings IEC, UL/CSA

General information on the rated current and the rated voltage at EMC products
Rated Voltage
Rated current

The values are different depending on the approval body and therefore are referenced in the corresponding admission cards for the respective product families. Details about the approvals and ratings are listed in the data sheets.

Search approval information for different families

Approvals

1 - 10 A @ Ta 40 °C / 250 VAC; 60 Hz

Leakage Current

Leakage Current


The leakage current is an electric current flowing in an undesirable current path. In EMC filters this is done by the applied Y-capacitors, which are used for noise suppression. Information on the amount and classification of leakage currents are explained in detail and are listed in the data sheets.
Leakage Current

standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)

Dielectric Strength

Dielectric Strength


Information abou the maximum permissible voltage, to avoid a voltage breakdown due to insulation damage.

Dielectric Strength

> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)

Allowable Operation Temperature

-25 °C to 85 °C

Climatic Category

Climatic Category


Disposition of components in categories for the assessment of mechanical and electrical properties.
Climatic Category

25/085/21 acc. to IEC 60068-1

IP-Protection

IP-Protection


The IP code consists of a two-digit number, which indicates the respective degree of protection.

The first digit specifies the protection from the penetration of foreign objects, the second digit the protection from water penetration with harmful effects.

Details about IP protection degree can be looked up in the general product information
IP-Protection

from front side IP40 acc. to IEC 60529

Protection Class

Protection Class


Class I: with ground; Class II: without ground

Detailed information relating to protection class can also be found in the general product information

Insulation cover

Suitable for appliances with protection class I acc. to IEC 61140

Terminal

Terminals


Terminals according IEC Standard.

Detailed information about terminals can be looked up in the date sheet or in the general product information.
Terminal

Solder terminals 3.5 x 0.8 mm or quick connect terminals 6.3 x 0.8 mm

Panel Thickness S

Panel Thickness S



See details in drawing
Snapper

Snap-in: 1/1.2/1.5/2/2.5/3 mm1/1.2/1.5/2/2.5/3 mm

Material: Housing

Thermoplastic, black, UL 94V-0

appliance inlet/-outlet

appliance inlet/-outlet


Connector type according to IEC 60320-1 resp. IEC 60320-2-2, UL498, CSA C22.2 no.42

Details on connectors and their names can be found in the general product information
Appliance Couplers
Mating Connectors
Term explanation
Special Connector Designs

C14 acc. to IEC 60320-1,
F acc. to
UL 498, CSA C22.2 no. 42 (for cold conditions) pin-temperature 70 °C, 10 A, Protection Class I

Fuseholder

Fuseholder


1.) fuse holder does not include circuit breakers

2.) Details about fuse-links can be found in the catalog under   Fuses

Detailed information on the fuse holder and fuse drawers can be found in the general product information.
Fuse drawer

1 or 2 pole, Shocksafe category PC2 acc. to IEC 60127-6,
for fuse-links 5 x 20 mm

Rated Power Acceptance @ Ta 23 °C

5 x 20: 2 W (1 pole)/ 1.6 W (2-pole) per pole

Power Acceptance @ Ta > 23°C

Admissible power acceptance at higher ambient temperature see derating curves

Line Switch

Fuseholder


1.) fuse holder does not include circuit breakers

2.) Details about fuse-links can be found in the catalog under   Fuses

Detailed information on the fuse holder and fuse drawers can be found in the general product information.
Fuse drawer

Rocker switch 2-pole, non-illuminated, acc. to IEC 61058-1
Technical Details

Line Filter

Filter Type


Filter classification according leakage current for easy reading:

Standard: < 0.5 mA
Medical: < 0.1 mA

Standard Version, IEC 60939, UL 1283, CSA C22.2 no. 8
Technical Details

MTBF

MTBF


The term MTBF is the English acronym Mean Time Between Failure and describes reliability of a component. The operating time of a system can be calculated based on thementioned value of the component. - The higher this value, the more reliable the component.
MTBF

> 1'400'000 h acc. to MIL-HB-217 F

Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in  Details about Approvals

SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF 16949, medical technology according to ISO 13485 or in the aerospace industry can be offered exclusively with customer-specific, individual agreements by SCHURTER.


Approvals

The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.


Approval Reference Type: Felcom

Approval Logo Certificates Certification Body Description
Approval marks ENEC 10 VDE Certificate Number: 101307
Approval marks cURus UL UL File Number: E72928


Product standards

Product standards that are referenced

Organization Design Standard Description
Partners IEC_Certification_Body Designed according to IEC 60320-1 Appliance couplers for household and similar general purposes
Partners IEC_Certification_Body Designed according to IEC 60939 Passive filters for suppressing electromagnetic interference
Partners IEC_Certification_Body Designed according to IEC 60127-6 Miniature fuses. Part 6. Fuse-holders for miniature fuse-links
Partners IEC_Certification_Body Designed according to IEC 61058-1 Switches for appliances. Part 1. General requirements
Partners UL_Certification_Body Designed according to UL 498 Standard for Attachment Plugs and Receptacles
Partners UL_Certification_Body Designed according to UL 1283 Electromagnetic interference filters
Partners CSA_Certification_Body Designed according to CSA C22.2 no. 42 General Use Receptacles, Attachment Plugs, and Similar Wiring Devices
Partners CSA_Certification_Body Designed according to CSA C22.2 no. 8 Electromagnetic interference (EMI) filters


Application standards

Application standards where the product can be used

Organization Design Standard Description
Partners IEC_Certification_Body Designed for applications acc. IEC/UL 60950 IEC 60950-1 includes the basic requirements for the safety of information technology equipment.
Partners IEC_Certification_Body Designed for applications acc. IEC 60601-1 Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
Partners IEC_Certification_Body Designed for applications acc. IEC 60335-1 Safety of electrical appliances for household and similar purposes. Meets the requirements for appliances in unattended use. This includes the enhanced requirements of glow wire tests acc. to IEC 60695-2-11 or -12 & -13.


Compliances

The product complies with following Guide Lines

Identification Details Initiator Description
Approval marks CE Selbsteklaration SCHURTER AG The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008.
Environment_Safety RoHS_Logo_color_CMYK_tif SCHURTER AG Directive RoHS 2011/65/EU, Amendment (EU) 2015/836
Environment_Safety China_RoHS_e_konform_eps SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS.
Environment_Safety REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force.
Environment_Safety Glow_Wire_Proof SCHURTER AG Meets the requirements of IEC 60335-1 for appliances in unattended use. This includes the enhanced requirements of glow wire tests acc. to IEC 60695-2-11 or -12 &-13.
Environment_Safety Medical.jpg SCHURTER AG Suitable for use in medical equipment according to IEC/UL 60601-1

Preview
 

Picture(s) Selection of product pictures to display a specific variant of the type

Type
 

Type Corresponds to a product series and includes various distinct variants. On the type of descriptive data are summarized, eg in the data sheet

Order Number
 

Order Number Unique part number for placing an order

Configuration key
 

Configuration key The configuration key of a product consists of the composite key values, which describe the different kinds of attribut distinction.

Comment
 

Comment CAD drawings are for modeling purposes only

Model Description
 

Model Description Abbreviated description of the CAD model

IGS
 

IGS Also mentioned as IGES ( Initial Graphics Exchange Specification). Common program indipendent interchange format for 3D CAD data.

Step
 

Step Also mentioned as STEP ( Standard for the Exchange of Product Model Data). Common program indipendent interchange format for 3D CAD data standardized according ISO standard.

Parasolid
 

Parasolid Parasolid modeling kernel is a 3D CAD systems. It is developed by a separate business unit within the Unigraphics Solutions (UGS), now Siemens PLM Software.

DXF
 

DXF (Drawing Interchange Format) is a specified by the Autodesk file format for CAD data exchange, and was developed for the 2D-CAD program AutoCAD. A DXF file describes a CAD model as plain text to the ASCII standard.

Felcom 54
5432.1151.121 5432.1153.251 5432.1253.153 5432.1253.201 5432.2153.151 5432.2253.121 5432.2253.201 5432.2253.251 5432.2253.253 5432.4153.251 5432.4251.201 5432.4253.151 5432.4253.201 5432.6153.251 5432.6251.201 5432.6253.101 5432.6253.151 5432.6253.301 5432.6253.303
5432.XXXX.XX CAD-Model shows variation appliance inlet with fuse, rocker switch and appliance outlet with snap-in 3.0 mm, Terminal 6.3x0.8 mm
Felcom 54
5411.1151.151 5411.1151.251 5411.1153.151 5411.1251.203 5411.1253.101 5411.1253.151 5411.1253.251 5411.2151.121 5411.2153.151 5411.2153.251 5411.2251.251 5411.2253.123 5411.2253.151 5411.2253.201 5411.2253.301 5411.4153.251 5411.4253.103 5411.4253.151 5411.4253.153 5411.4253.201 5411.4253.251 5411.6253.121 5411.6253.151 5411.6253.201 5411.6253.253
5411.XXXX.XX CAD-Model shows variation appliance inlet with fuse holder with snap-in 3.0 mm, Terminal 6.3x0.8 mm
Felcom 54
5421.1053.201 5421.2051.201 5421.4053.151
5421.XXXX.XX CAD-Model shows variation appliance inlet and appliance outlet with snap-in 3.0 mm, Terminal 6.3x0.8 mm
Felcom 54
5423.2153.151 5423.4253.151 5423.4253.201 5423.6253.151 5423.6253.201 5423.6253.301
5423.XXXX.XX CAD-Model shows variation appliance inlet with fuse holder and appliance outlet with snap-in 3.0 mm, Terminal 6.3x0.8 mm
Felcom 54
5424.1150.201 5424.1151.151 5424.1151.201 5424.1151.301 5424.1153.151 5424.1153.201 5424.1153.203 5424.1153.301 5424.1153.303 5424.1251.101 5424.1251.151 5424.1251.201 5424.1251.203 5424.1253.101 5424.1253.151 5424.1253.153 5424.1253.201 5424.1253.301 5424.1253.303 5424.2151.151 5424.2151.201 5424.2151.251 5424.2151.301 5424.2153.101 5424.2251.203 5424.2251.301 5424.2253.103 5424.2253.121 5424.2253.153 5424.2253.201 5424.2253.203 5424.2253.251 5424.2253.253 5424.2253.301 5424.4153.151 5424.4153.251 5424.4251.201 5424.4253.101 5424.4253.103 5424.4253.151 5424.4253.153 5424.4253.201 5424.4253.203 5424.4253.251 5424.4253.301 5424.4253.303 5424.6151.151 5424.6153.121 5424.6153.151 5424.6153.153 5424.6253.101 5424.6253.121 5424.6253.151 5424.6253.201 5424.6253.251 5424.6253.301
5424.XXXX.XX CAD-Model shows variation appliance inlet with fuse holder and rocker switch with snap-in 3.0 mm, Terminal 6.3x0.8 mm
Felcom 54
5431.1051.101 5431.2053.101 5431.6053.301
5431.XXXX.XX CAD-Model shows variation appliance inlet, rocker switch and appliance outlet with snap-in 3.0 mm, Terminal 6.3x0.8 mm

Dimension [mm]

Variants 5411.XX5X.XXX
Mounting hole: 63 +0.2 x 27,6 +0.2
A: Quick-connect terminal 6.3x0.8 mm: 22 mm
A: Solder terminal 3.5x0.8 mm: 17.5 mm
S: Panel thickness␉
Variants 5421.X05X.XXX
Mounting hole: 85.9+0,2 x 27.6+0,2
A: Quick-connect terminal 6.3x0.8 mm: 22 mm
A: Solder terminal 3.5x0.8 mm: 17.5 mm
S: Panel thickness␉
Variants 5423.XX5X.XXX
Mounting hole: 96.4+0,2 x 27.6+0,2
A: Quick-connect terminal 6.3x0.8 mm: 22 mm
A: Solder terminal 3.5x0.8 mm: 17.5 mm
S: Panel thickness␉
Variants 5424.XX5X.XXX
Mounting hole: 87.9+0,2 x 27.6+0,2
A: Quick-connect terminal 6.3x0.8 mm: 22 mm
A: Solder terminal 3.5x0.8 mm: 17.5 mm
S: Panel thickness␉
Variants 5431.X05X.XXX
Mounting hole: 111.1+0,2 x 27.6+0,2
A: Quick-connect terminal 6.3x0.8 mm: 22 mm
A: Solder terminal 3.5x0.8 mm: 17.5 mm
S: Panel thickness␉
1) In an uninstalled state the total length of the combinations may be slightly bigger than the nominal dimension. However, they can always be installed in the specified mounting cutouts.
Variants 5432.XX5X.XXX
Mounting hole: 121.6+0,2 x 27.6+0,2
A: Quick-connect terminal 6.3x0.8 mm: 22 mm
A: Solder terminal 3.5x0.8 mm: 17.5 mm
S: Panel thickness␉
1) In an uninstalled state the total length of the combinations may be slightly bigger than the nominal dimension. However, they can always be installed in the specified mounting cutouts.

Diagrams

5411

1) Line
2) Load 1
5421

1) Load 2
2) Load 1
5423

1) Load 2
2) Load 1
5424

1) Line
2) Load 1
5431

1) Load 2
2) Load 1
5432

1) Load 2
2) Load 1

Derating Curves

1-pole

Admissible power acceptance in Watt
Ambient air temperature Ta °C

2-pole

Admissible power acceptance in Watt per pole
Ambient air temperature Ta °C


Technical Data of Filter-Components

Rated Current [A] Filter-Type Inductances L [mH] Capacitance CX [nF] Capacitance CY [nF] R [MΩ]
1 Standard Version 2 x 11 47 2.2 -
2 Standard Version 2 x 4 47 2.2 -
4 Standard Version 2 x 1.6 47 2.2 -
6 Standard Version 2 x 0.7 47 2.2 -
8 Standard Version 2 x 0.6 47 2.2 -
10 Standard Version 2 x 0.4 47 2.2 -
1 Medical Version (M5) 2 x 11 47 - 1
2 Medical Version (M5) 2 x 4 47 - 1
4 Medical Version (M5) 2 x 1.6 47 - 1
6 Medical Version (M5) 2 x 0.7 47 - 1
8 Medical Version (M5) 2 x 0.6 47 - 1
10 Medical Version (M5) 2 x 0.4 47 - 1

Short Table of Variants Felcom 54 Open complete table Felcom 54


Type Rated Current [A] Filter-Type Order Number

Variant Details


The link on the respective order number refers to a separat tab with specific detailed information .

This assures better readable information of the selected product.
Change to the tab All Products in order to show details of another variant.

This approach offers to use generic alias link to the product details:

www.schurter.xx/art/ [Order Number]

where the following variables are used:
- xx is the country specific domain
- [Order Number]

A=Most Popular

A=Most Popular


Most popular products have the following customer benefits:

- previously ordered by multiple customers
- generally in stock for immediate delivery
- early adoption or mature life cycle

Contact us for availability on other product variants, lead-times vary:
Contact-Form

Availability for all products can be searched real-time. Enter part number and required quantity:
Stock Check SCHURTER

Free Sample

Free Sample


Please ask for free sample in order to check if the products meets your requirement for your application. Send your delivery adress and your specific requirements.

Distributor Stock Check

Distributor Stock Check


The following links reffers to the inquiry form for distributors stock information of the selected products. It allows checking for the available amount and optionally to place an order at your selected partner.

The
Distributor Stock Check
Stock Check Distributor

...
  [A]              
 
Felcom 54 1 Standard Version 5411.1151.151 ...
Felcom 54 1 Standard Version 5411.1151.251 ...
Felcom 54 1 Standard Version 5411.1253.151 ...
Felcom 54 1 Standard Version 5421.1053.201 ...
Felcom 54 1 Standard Version 5424.1151.151 ...
Felcom 54 1 Standard Version 5424.1151.201 ...
Felcom 54 1 Standard Version 5424.1151.301 ...
Felcom 54 1 Standard Version 5424.1153.201 ...
Felcom 54 1 Standard Version 5424.1153.301 ...
Felcom 54 1 Standard Version 5424.1253.101 ...
Felcom 54 1 Standard Version 5424.1253.151 ...
Felcom 54 1 Standard Version 5424.1253.201 ...
Felcom 54 1 Standard Version 5424.1253.301 ...
Felcom 54 1 Standard Version 5432.1153.251 ...
Felcom 54 1 Standard Version 5432.1253.201 ...
Felcom 54 1 Medical Version (M5) 5411.1251.203 ...
Felcom 54 1 Medical Version (M5) 5424.1251.203 ...
Felcom 54 1 Medical Version (M5) 5424.1253.153 ...
Felcom 54 1 Medical Version (M5) 5424.1253.303 ...
Felcom 54 2 Standard Version 5411.2151.121 ...
Felcom 54 2 Standard Version 5421.2051.201 ...
Felcom 54 2 Standard Version 5424.2151.151 ...
Felcom 54 2 Standard Version 5424.2151.251 ...
Felcom 54 2 Standard Version 5424.2153.101 ...
Felcom 54 2 Standard Version 5424.2253.121 ...
Felcom 54 2 Standard Version 5424.2253.201 ...
Felcom 54 2 Standard Version 5424.2253.301 ...
Felcom 54 2 Standard Version 5431.2053.101 ...
Felcom 54 2 Standard Version 5432.2153.151 ...
Felcom 54 2 Standard Version 5432.2253.121 ...
Felcom 54 2 Standard Version 5432.2253.201 ...
Felcom 54 2 Standard Version 5432.2253.251 ...
Felcom 54 2 Medical Version (M5) 5411.2253.123 ...
Felcom 54 2 Medical Version (M5) 5424.2251.203 ...
Felcom 54 2 Medical Version (M5) 5424.2253.153 ...
Felcom 54 2 Medical Version (M5) 5424.2253.203 ...
Felcom 54 4 Standard Version 5411.4253.151 ...
Felcom 54 4 Standard Version 5411.4253.251 ...
Felcom 54 4 Standard Version 5421.4053.151 ...
Felcom 54 4 Standard Version 5423.4253.151 ...
Felcom 54 4 Standard Version 5424.4153.151 ...
Felcom 54 4 Standard Version 5424.4253.101 ...
Felcom 54 4 Standard Version 5424.4253.151 ...
Felcom 54 4 Standard Version 5424.4253.201 ...
Felcom 54 4 Standard Version 5424.4253.251 ...
Felcom 54 4 Standard Version 5432.4153.251 ...
Felcom 54 4 Standard Version 5432.4251.201 ...
Felcom 54 4 Standard Version 5432.4253.151 ...
Felcom 54 4 Standard Version 5432.4253.201 ...
Felcom 54 4 Medical Version (M5) 5411.4253.103 ...
Felcom 54 4 Medical Version (M5) 5424.4253.103 ...
Felcom 54 4 Medical Version (M5) 5424.4253.153 ...
Felcom 54 4 Medical Version (M5) 5424.4253.203 ...
Felcom 54 4 Medical Version (M5) 5424.4253.303 ...
Felcom 54 6 Standard Version 5411.6253.151 ...
Felcom 54 6 Standard Version 5411.6253.201 ...
Felcom 54 6 Standard Version 5423.6253.151 ...
Felcom 54 6 Standard Version 5423.6253.201 ...
Felcom 54 6 Standard Version 5423.6253.301 ...
Felcom 54 6 Standard Version 5424.6151.151 ...
Felcom 54 6 Standard Version 5424.6153.121 ...
Felcom 54 6 Standard Version 5424.6153.151 ...
Felcom 54 6 Standard Version 5424.6253.101 ...
Felcom 54 6 Standard Version 5424.6253.151 ...
Felcom 54 6 Standard Version 5424.6253.201 ...
Felcom 54 6 Standard Version 5424.6253.251 ...
Felcom 54 6 Standard Version 5424.6253.301 ...
Felcom 54 6 Standard Version 5432.6251.201 ...
Felcom 54 6 Standard Version 5432.6253.101 ...
Felcom 54 6 Standard Version 5432.6253.151 ...
Felcom 54 6 Standard Version 5432.6253.301 ...
Felcom 54 6 Medical Version (M5) 5411.6253.253 ...
Felcom 54 8 Standard Version 5411.6253.121 ...
Alternative: version without line filter (1)

[Swipe to the left and right for more options]

Alternative: Standard version (0)

[Swipe to the left and right for more options]

Mating Inlets/Plugs (6)

[Swipe to the left and right for more options]

4732

4732, Mounting: Power Cord, Plug: IEC E, Cable

4735

4735, Mounting: Power Cord, Plug: IEC E, Cable

9009

9009, Mounting: Plug: IEC E, Screw clamps

4733

4733, Mounting: Power Cord, Plug: IEC E, Cable

4736

4736, Mounting: Power Cord, Plug: IEC E, Cable

P685

p685, Mounting: Power Cord, Plug: IEC E, Cable

Mating Outlets/Connectors (13)

[Swipe to the left and right for more options]

4787

4787, Mounting: Screw-on mounting, Appliance Outlet: IEC Solder terminals, 10 A, Suitable for appliances with protection class I

4788

4788, Mounting: Snap-in version, Appliance Outlet: IEC Solder terminals or quick connect terminals, 10 A, Suitable for appliances with protection class I

5091

IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal

4022

4022 Mounting: Power Supply Cord, 3 x 1.5 mm², Screw clamps, Connector: IEC C13

4782

4782 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13

4012

4012 Mounting: Power Supply Cord, 3 x 1 mm², Screw clamps, Connector: IEC C13

4785

4785 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13

4300-06

4300-06 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13

4781

4781 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C15

8101

8101 Mounting: Power Supply Cord, 3 x 1.5 mm², Screw clamps, Connector: IEC C15

4784

4784 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C15

4771

4771 Mounting: Power Supply Cord, 3 x 1 mm² / 3 x 14 AWG, Screw clamps, Connector: IEC C15A

4772

4772 Mounting: 3 x 1 mm² / 3 x 14 AWG, Screw clamps, Connector: IEC C15A

Accessories (1)

[Swipe to the left and right for more options]

Cord retaining kits

Cord retaining strain relief